Installation
Instructions
Experience In Motion
SLM-6200
Self contained cartridge
medium duty slurry seal
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - Instructions

Installation InstructionsExperience In MotionSLM-6200 Self contained cartridge medium duty slurry seal

Página 2

106.2 Remove the setting plate screws. With a screwdriver, pry the setting plates clear of the gland and remove them. Keep the setting plates and scr

Página 3 - 2 Recommendations

117.2 Connect the seal gland barrier outlet (BO) port to the return side of the external system. 3/4” tubing is recommended for the seal circulation

Página 4 - 3 General Instructions

TO REORDER REFER TOB/M #F.O.FIS159eng REV 7/13 Printed in USAflowserve.comTo find your local Flowserve representativeand find out more about Flowserve Co

Página 5

1 Cartridge Installation InstructionsThe following instruction manual is designed to simplify the installation of the SLM-6200 slurry seal. The SLM-6

Página 6

32.4 Shaft radial runout should be less than 0.0005 mm per mm (0.0005 inch per inch) of shaft/sleeve diameter. See Figure 3. Turn the shaft through 3

Página 7

42.6 Ensure that the shaft or shaft sleeve has a 1.6 mm (0.06 inch) x 30° chamfer on the leading edge to prevent O-ring damage at seal installation.2

Página 8

53.6 For adapters provided with a centering jig, simply insert the centering jig into the adapter and tighten adapter bolts, alternately adjusting th

Página 9 - 6 Completing Installation

64.2 Seal chamber concentricity should be less than 0.38 mm (0.015 inch). See Figure 8. Seal life varies with alignment. Poor shaft alignment will re

Página 10 - 7 Barrier Fluid Piping Plans

7 4.7 Check the orientation of the gland ports and reposition as necessary. See Figure 6.4.8 Insert the retaining screws through the rear face of th

Página 11 - Slurry Seal

85.3 With the seal clamp collar facing toward the bearing assembly, slide the complete cartridge over the pump shaft/sleeve and push back toward the

Página 12 - 10 Repair

9 5.9 Slide the seal cartridge up to the equipment case. Insert the gland retaining bolts through the gland holes and screw into the threaded holes o