Flowserve RIS Seal Manual do Utilizador Página 7

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 12
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 6
7
4.4 Position9and 9-1jamnutsasfaraspossibletoeachendof10
studsotheywillnotrestrictaxialmovementof101clampring.
4.5 Installrotatingfaceassembly.SeeFigure7.
4.5.1 Cleantheendoftheshaftsleeveofanydirt(orshaft
shoulderifasleeveisnotused)andremoveanynicks
or burrs.
4.5.2 Clean both rotating and stationary seal faces with
alcohol by applying it to a lint free tissue and wiping the
sealface.Makesurealldirtandgreaseareremoved.
4.5.3 Install the gasket(s) as shown on the seal assembly
drawing.
4.5.4 Install the assembly onto the shaft.
4.6 Install the pump impeller.
4.6.1 Apply grease to the impeller threads only.
4.6.2 Install the appropriate gasket or O-ring as described on
the form drawing.
4.6.3 Be sure the impeller is tight after assembly.
Assemble the Rotating Face Assembly Figure7
Impeller
SealCarrier
240
Bolt
40
Clamp Ring
101
Stud10
Bolt
40-1
Jam Nut
9
EndPlate139
O-ring
71
Cover
46
Jam Nut
9-1
Vista de página 6