Limitorque QX Electronic Actuator FCD LMENIM3314-00 – 5/11
58
Figure 6.5 - Control Module Assembly
6.3.1 Control Module Removal
Step 1
Using a M3 hex key remove screw (# 14-12) and retainer (#14-11 ). Disconnect all wiring harnesses.
Step 2
Using a M3 hex key, loosen the three M4 mounting screws (#14-9) that mount the Control module subassembly.
Slightly rotate the complete control module subassembly in a counterclockwise (CCW) direction until the keyholes
slots in the control module chassis plate (#1-1) allow the head of the screws to pass thru and remove controls
subassembly.
6.3.2 Control Module Subassemblies
Table 6.6 - Low Voltage (Less than 250 VAC) Control Module Subassembly
ITEM NUMBER DESCRIPTION QTY.
1-1 CHASSIS PLATE 1
1-2 MOTOR CONTROLLER BOARD 1
1-7 SHIELD 1
1-8 PAN HEAD CAP SCREW 4
1-9 COVER, IRAM 1
1-10 RIBBON CABLE 1