Flowserve CPM Series Manual do Utilizador Página 6

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 8
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 5
6
2.8 Rotate the setting devices 180°
from the sleeve drive collar and
retighten. See Figure 6.
Loosen the hex head bolts
attaching the bronze centering
devices to the gland setting
devices, rotate 180° to clear the
drive collar. Retighten the hex head
bolts to store the tabs on the gland.
2.9 Turn the shaft by hand to ensure
unobstructed operation.
2.10 See Operational
Recommendations before
start-up.
3 Operational Recommendations
3.1 Install an adequate seal ush system. The CPM PX requires a
clean cool environment for maximum seal life. With a clean cool
product, use a bypass ush from the pump discharge (plan 11)
or a bypass ush to the pump suction (plan 13). With a clean
hot product, use a bypass ush through a cooler (plan 21) or
circulation from the seal chamber through a cooling system (plan 23).
With abrasive products or products that are incompatible with the
seal, use a ush from a clean external source (plan 32).
3.2 Remove lock outs on pump and valves.
3.3 Do not start up the equipment dry to check motor rotation, etc.
Open valves to ood pump with product uid. Ensure that the seal
ush system is operating. Vent air from the casing of the pump and
the seal chamber before start-up.
3.4 Observe the start-up. If the seal runs hot or squeals, check the
seal ush system. Do not allow the equipment to run for any
extended time if the seal gets hot or squeals.