4
2.4 Align anti-rotation tabs of wiper
sealsverticallyandspaceaxially
approximatedistancetomatchID
ofbearing.Positionsuchthatthe
lower wiper seal is 25 to 50 mm
(1to2inches)abovethemounting
plate.
2.5 Placeonehalfofcarrierassembly
ontoshaft,ensuringthatanti-
rotation tabs are fully engaged to
theIDofthebearing.The spheri-
cal section of the carrier assembly
should point down and the straight
section of the carrier should point
up.
2.6 Jointhematinghalfinthesame
orientationandsecurebearing
assemblybyinstallingthefour(4)
capscrews.Tightencapscrewsto
atorquevalueof2.3N-m
(20in-lbs).
2.7 Applyalightcoatingofhigh
temperaturegreaseintheO-ring
grooveontheoutsideofthecarrier
assembly.PlaceO-ringcordinthe
groovesothetwoendsmeeton
eithersideoftheanti-rotationpin.
The grease should hold the O-ring
in place.