Centering and Attachment Screws Figure 3
Itisessentialthatbeforetighteningboltsthemotor/gearbox/seal
assembly center of mass be found and that point used to lift the
sealhousingsintoposition.Theboltingtothemixerangeshould
becompletebeforethesupportforthemotor/gearbox/sealis
removed.
2.1.3 Lower the shaft through the seal cartridge. Great care must be
taken to avoid any binding that may cause the seal hardware to
support the shaft.
2.1.4 When the shaft has threaded through the seal attach the shaft
as required to the mixer drive. Takecaretoinsurethattheshaft
isstraightandconcentricwiththeboreofthemixerange.Follow
mixer drive manufacturer re dations.
2.1.5 After the shaft is in its nal operating position and no more
adjustmentswillbemadetothepositionoftheshaft,doublecheck
thesealcanisterandtightencanisterboltingtothemixerange
and/ormixerdrive.
2.1.6 Attach the rotating portion of the seal to the shaft. Thesealyou
areinstallingisdesignedtotyourspecicpieceofequipment.
Withthisinmindrefertothedrawingspecictothissealandyour
equipment. Note that there may be small differences from this
instruction in how this step is accomplished. See Figure 3.
57
5 7.1
57.2
Vista de página 4
1 2 3 4 5 6 7 8

Comentários a estes Manuais