Step 7 Observe the length of the
lock pin outside of the gland.
The pin should extend
2.5 to 4.8 mm (0.10 to 0.19
inch) from the gland. If it is
more or less than this,
remove the gland and
recheck the installation.
Step 8 Pry off the centering devices
with a screwdriver.
Step 9 Connect the ush line to the gland if required.
Step 10 Turn the shaft by hand as a nal check to be sure nothing is binding.