6
Notes for Figure 3:
• Recommendationsareforuseinwaterorothersimilarviscosityliquids.
• Theserecommendationsapplytoproductshavingamaximumtempera-
ture of 71°C (160°F).
• Onverticalequipment,usePlan13toventthesealareaevenwhen
operating in zone B
Cooling Recommendations for PSS II Figure 3
Ifthesealrunshot,checkforpropersealsetting,seeStep7,andchecktheush
line for obstructions.
For special problems encountered during installation, contact your nearest
FlowserveSalesandServiceRepresentativeorAuthorizedDistributor.
Operational Recommendations
Do not start up the equipment dry.Ventairfromthestufngboxbefore
startup.Circulatecleanproduct,Plan11,oracleanuidfromanexternalsource,
Plan32,throughthesealchamberwhenevertheequipmentisinoperationun-
lessoperatinginZoneBofFigure3wherenoushisrequired.
3600
2700
1800
900
RPM
By-pass flush Plan 11, or
Externa
Not Recommended,
Exceeds PSS II
Speed Limitations
Seal Size
Zone
Zone C
(38.1 to
50.8 mm)
1.500 to
2.000"
(54.0 to
76.2 mm)
2.125 to
3.000"
(79.4 to
101.6 mm)
3.125 to
4.000"
(104.8 to
127.0 mm)
4.125 to
5.000"
(130.2 to
152.4 mm)
5.125 to
6.000"
Flush Recommended to Keep Stuffing Box Clean
No Flush Required for Cooling of Seal, Vent Required
Can be Run Dead-Ended Plan 02