Flowserve XL90 Series Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
XL90 Part Numbering System
PREFIX
Selection Code
Automax Manufacture - Black Epoxy MB
Automax Manufacture - White Food Grade Epoxy MW
Accord Manufacture - Black Epoxy AB
Accord Manufacture - White Food Grade Epoxy AW
Sereg Manufacture - White Epoxy SW
Valtek Manufacture - White Epoxy VW
INPUT MODEL
Selection Code
Pneumatic Input 3-15 psi 90
Electro-Pneumatic Input 4-20mA 91
General Purpose NT3000
Electro-Pneumatic Input 4-20mA 92
FM/CSA Explosion Proof and Intrins. Safe NT3000
Electro-Pneumatic Input 4-20mA 93
CENELEC EExd (Explosion Proof) NT3000
Electro-Pneumatic Input 4-20mA 94
CENELEC EExia & EExib (Intrinsically Safe) NT3000
INDICATION
Selection Code
Flat Lens with Green Indicator 1
(Standard)
Ultradome with Green Indicator U
Cover for top-mounted Namur UltraSwitch T
(includes UltraSwitch mounting kit)
GAGES
Selection Code
3 Stainless Steel Gages with Brass Fittings 2
(Standard)
2 Stainless Steel Gage with Brass Fitting 3
(Standard)
3 Stainless Steel Gages 4
2 Stainless Steel Gages 5
No Gages 6
TEMPERATURE
Selection Code
Standard Temperature (Buna-N soft goods) 7
Extended Temperature (Fluorosilicone soft goods) 8
CAM
Selection Code
Accord Linear Cam A
Accord 30, 45, 60 & 90 Degree Linear Cam B
Accord Linear, Square, Square Root (Damper) Cam C
Accord 0-60 Degree Cam (Butterfly Valves) D
Sereg Linear and =% Cam - Diaphragm Actuator E
Valtek Linear Cam - Piston Actuator F
Valtek =% Cam-Piston Actuator-Rotary Valve G
CONDUIT THREAD CONNECTION
Selection Code
1/2" NPT (Standard) P
M20 Threads R
OPTIONS - As Needed (See notes 1-4 below)
ANALOG OUTPUTS
Selection Code
4-20mA Transmitter F
or
INTERNAL LIMIT SWITCHES
2-SPDT Mechanical Switches with High Resolution Cams J
2-SPDT Mechanical Switches K
2-SPST Proximity Switches M
2-SPDT Proximity Switches N
2-Intrinsically Safe Solid State Proximity Switches Q
Conduit
Input Temp- Thread
Prefix Model Indication Gages erature Cam Connection Option
48-12 Flowserve Corporation, Valtek Control Products, Tel. USA 801 489 8611
Notes: 1. Internal limit switches and an internal transmitter cannot be used simultaneously.
2. When options F, J, K, M, or N are used with an I/P transducer, input model number 91 must be used.
3. When option Q is used with an I/P transducer, input model numbers 90 or 92 must be used.
4. Internal limit switches or an internal transmitter cannot be used in an explosion proof environment. As an alternative, the explosion proof UltraSwitch may be mounted on
top of the positioner. (Use option T.)
5. Namur shaft end connections are standard for Automax and Accord positioners, Double D shaft end connections are standard for Sereg and Valtek positioners. Contact
factory for exceptions to this standard.
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Comentários a estes Manuais

Sem comentários