1 Nomenclature
Notes: - Inboard stator (3A) is interchangeable with outboard stator (3).
- Inboard mating ring (3C) is interchangeable with outboard mating ring (3B).
- Inboard stator carrier (SC1) is interchangeable with outboard stator carrier (SC).
- Primary seal O-rings (P, P1, P2, P3, 6, 6A) are all the same size and cross section.
Figure 1
SL 6A P3
SC1
RR M
1CP
3C 3A
3
13 9
SCP26141B
C1
P1
G
G1
M1
11A
3B KCT13AB
11 10A
3 Outboard Stator
3A Inboard Stator
3B Outboard Mating Ring
3C Inboard Mating Ring
C Outboard Springs
C1 Inboard Springs
SC Outboard Stator Carrier
SC1 Inboard Stator Carrier
P Outboard Dynamic O-ring
P1 Inboard Dynamic O-ring
P2 Outboard Stator O-ring
P3 Inboard Stator O-ring
6 Outboard Mating Ring O-ring
6A Inboard Mating Ring O-ring
G Gasket
G1 Inner Gland O-ring
Table 1
1 Gland Assembly
B Carbon Bushing
1B Inner Gland
14 Rotor Carrier
RR Retaining Ring
CT Centering Tab
K Centering Tab Cap Screw
SL Sleeve Assembly
10A Drive Ring
M Outboard Vibration Dampner
M1 Inboard Vibration Dampner
9 Sleeve Collar
13 Cup Point Set Screw
13A Quarter Dog Set Screw
11 Shaft O-ring
11A Rotor Carrier O-ring
These instructions are written for trained, experienced technicians familiar with the basic
principles and tools involved in the installation, care and service of mechanical seals and seal
support systems. A complete reading of these instructions by personnel in contact with the
equipment is essential to safety. Incorrect installation, operation or maintenance can result in