Flowserve PMV D3 Digital Positioner Manual do Utilizador Página 42

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 60
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 41
42
• Tighten the screws F, on the cam assembly.
Do not tighten the screws to hard. The cams
should be able to move in relation to each
other.
• Install the inner cover with the two screws,
G.
• Connect the wiring for the transmitter feed-
back on the terminal block, according to the
drawing on next page.
Adjust the position where the switches/
sensors should be affected, by turning the
cams with a screwdriver.
• Tighten the cam assembly screws F when
the cams are correctly adjusted.
• Install the indicator and cover.
To calibrate the feedback transmitter, see
drawing on next page.
F
G
F
Vista de página 41