Flowserve PA46 Manual do Utilizador Página 23

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 22
23
Torques
All torques indicated in the table are based at a room temperature of 20 °C.
Maintenance  continued 
Tools
Spanner A. F. 13 mm, DIN 3113, Form B
Spanner A. F. 17 mm, DIN 3113, Form B
Spanner A. F. 28 mm, DIN 3113, Form B
Spanner A. F. 32 mm, DIN 3113, Form B
Spanner A. F. 36 mm, DIN 3113, Form B
Spanner A. F. 41 mm, DIN 3113, Form B
Torque spanner 1  12 Nm, ISO 6789
Torque spanner 20  120 Nm, ISO 6789
Torque spanner 80  400 Nm, ISO 6789
Socket spanner 13 x 250, DIN 3112
Punch 20 x 200, made of steel
Punch 20 x 200, made of CuZn (brass)
Pin punch 8 x 150, DIN 6450 C
Grease gun (for valve plug)
Item
Intermittent valves for removing boiler sludge Torques [Nm]
G
PA 46, PA 47, MPA 46, MPA 47 350
O
PA 46, PA 47, MPA 46, MPA 47 55
W
PA 46, PA 47, MPA 46, MPA 47 20
U
PA 46, PA 47 60
Y
MPA 46, MPA 47 120
5
MPA 46, MPA 47 5
Vista de página 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 31 32

Comentários a estes Manuais

Sem comentários