MK 25/2
MK 25/2S
Installation Instructions 810706-01
Steam Traps
MK 25 . .., DN 40-50
GESTRA Steam Systems
GESTRA
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - MK 25/2S

1MK 25/2MK 25/2SInstallation Instructions 810706-01Steam TrapsMK 25 . .., DN 40-50GESTRA Steam SystemsGESTRA

Página 2 - Contents

10Materials EN DIN ASTM equivalentBody P250GH (1.0460) C22.8 (1.0460) A105Cover MK 25/2 P250GH (1.0460) C22.8 (1.0460) A105Cover MK 25/2S GP240GH (1.

Página 3 - Capacity Chart

11Explanatory Notes – continued –Name Plate / MarkingFig. 7For further specifications to EN 19 see trap body.Capacity rating Capacity 2800 kg/h

Página 4 - Design MK 25/2

121. Take care of correct position of installation.2. Observe direction of flow. The flow arrow is on the trap body.3. Consider space required for ope

Página 5 - Design MK 25/2S

13CommissioningOperationPlease note that maintenance is required for certain operation modes (seeMaintenance).1. Take care of correct position of inst

Página 6 - Check Capsule

14 1. Take heed of note “Danger” on page 8. 2. Undo hexagon-head bolts A and remove cover B from trap body H. 3. Completely unscrew regulator R. 4

Página 7

15Designation Stock codeMK 25/2 MK 25/2 SRegulator with body gasket 098770 098774Capsule 5H21) 376174 376174Gasket2) 92

Página 8 - Important Notes

16AnnexWe hereby declare that the pressure equipment MK 25/2 and MK 25/2 S, nominalsizes DN 40 - 50, conform to the following European Directive: EC P

Página 12 - Installation

2ContentsUsage for the intended purpose ...8Safety note ...

Página 13 - Installation – continued –

20Great BritainFlowserve Flow Control (UK) Ltd.Burrel Road, Haywards HeathWest Sussex RH 16 1TLTel. 00 44 14 44 / 31 44 00Fax 00 44 14 44 / 31 45 57E-

Página 14 - Maintenance

3Capacity ChartFig. 1MK 25/2: Condensate temperature 10 K (degC)below saturation temperature.MK 25/2: Cold condensate at a temperature of20 °C (start-

Página 15 - Spare Parts

4Design MK 25/2Fig. 2ABCDEFHIGJR

Página 16 - Head of the Design Dept

5Design MK 25/2SFig. 3ABDFHIECGJR

Página 17

6Thermostatic capsule D for flat seat nozzle support: 5H2Capsule intactCapsule defectiveFig. 6Check CapsuleMLKFig. 5Fig. 4N≥ 4.4 mm≥ 3.8 mm

Página 18

7Hexagonal boltCoverCapsule holderCapsule 5 H2Nozzle seatGasket 92.7x 102x1StrainerBodyName plateHexagon nutDifferential pressure rating5 = ∆p 22 barI

Página 19

8Category INominal size DN 40 – 50 40 –50CE marking no yesTypeImportant NotesUsage for the intended purposeUse multi-capsule steam traps MK 25/2 and M

Página 20 - GESTRA AG

9Explanatory NotesScope of supplyMK 25/21 Steam trap MK 25/21 Installation manualMK 25/2S1 Steam trap MK 25/2S1 Installation manualDescriptionThermost